product-details__img

Mining polyethylene (PE) pipes

Execution Standards: MT181—1988 'Safety Performance Inspection Specification for Plastic Pipes Used in Coal Mines'; AQ1043—2009 'Safety Marking for Mining Products'; MT558.1—2005 'Plastic Pipes for Coal Mines Part 1: Polyethylene Pipes' Mining Indicators (MT558.1—2005): Surface resistivity varies depending on the pipe's application. Requirements are as follows: a) Water supply and drainage pipes: The arithmetic mean of the outer wall surface resistivity should not exceed 10 × 10⁹ Ω; b) Positive pressure ventilation ducts: The arithmetic mean of the inner and outer wall surface resistivity...


Share with friend

Description

Execution Standards: MT181—1988 'Safety Performance Inspection Specification for Plastic Pipes Used in Coal Mines'; AQ1043—2009 'Safety Marking for Mining Products'; MT558.1—2005 'Plastic Pipes for Coal Mines Part 1: Polyethylene Pipes' Mining Indicators (MT558.1—2005): Surface resistivity varies depending on the pipe's application. Requirements are as follows: a) Water supply and drainage pipes: The arithmetic mean of the outer wall surface resistivity should not exceed 10 × 10⁹ Ω; b) Positive pressure ventilation ducts: The arithmetic mean of the inner and outer wall surface resistivity...

3.jpg



Execution Standards:

MT181—1988 "Safety Performance Inspection Specification for Plastic Pipes Used in Coal Mines"

AQ1043—2009 "Safety Marking and Labeling for Mining Products"

MT558.1—2005 "Plastic Pipes Used in Coal Mines"

Part 1: Polyethylene Pipes Mining Specifications (MT558.1—2005): Surface FinishSurface resistance requirements vary depending on the application of the pipe: a) Water supply and drainage pipes: The arithmetic mean of the surface resistance of the outer wall should not exceed 10 × 10⁹ Ω b) Positive pressure air ducts: The arithmetic mean of the surface resistance of the inner and outer walls should not exceed 10 × 10⁸ Ω c) Shotcrete pipes: The arithmetic mean of the surface resistance of the inner and outer walls should not exceed 10 × 10⁸ Ω d) Negative pressure air ducts: The arithmetic mean of the surface resistance of the inner and outer walls should not exceed 10 × 10⁶ Ω e) Gas extraction pipes: The arithmetic mean of the surface resistance of the inner and outer walls should not exceed 10 × 10⁶ Ω**Alcohol Burning Test:** The alcohol burning test requirements for pipes are as follows: a) The arithmetic mean of the flaming time of 6 samples should not exceed 3 seconds, and the flaming time of any single sample should not exceed 10 seconds; b) The arithmetic mean of the flameless burning time of 6 samples should not exceed 20 seconds, and the flaming time of any single sample should not exceed 60 seconds.

Contact Us

If you have any questions about our products or services, please fill out the contact form below, and we will contact you promptly.

voldor image
back top
0.057195s